Compatibility SDK Bridge & Twain Integration Guide

Written on May 16, 2018

Compatibility: SDK/Direct integration; EOX Twain, IOS Twain -  Compatibility for Vatech Software & Devices

  • SDK- Direct Integration: from Practice Management to Vatech: EzDent-i/Easydent4 - Contact the 3rd party to setup their bridge.
  • EOX - Twain for 2D Pano/Ceph Modalities into 3rd party software - Contact Vatech Service
  • IOS - Sensor & Auto for IntraOral AutoAdvancement through twain capture into 3rd party capable software. - Download - Auto Advance Twain
  • Dattagrabber Functionality for Practice Management Software Bridging to EzDent-i / Easydent4 - Managed by PlanetDDS (Datagrabber is EOL (End of Life) and no longer offered by PlaentDDS.)

Note: Not all programs capable of twaining are listed, those listed are simply one's that have been confirmed to work. Most twain compliant programs  will support twain* generally with out issue. Please contact those software's that are not listed to confirm they support twain

Notice: Vatech does not install, troubleshoot or support the 3rd party integrations directly. Those requests should be directed to their respected manufactures.

 


 

Source Software   A - K Special Notes: To Apteryx/DG Bridge To EasyDent4 (SDK) To EzDent I (SDK) NCSW (SDK/Twain) Intra Oral SDK/Twain Auto Advance
ABEL Dent   F, DIA-XV        
Ace Users MUST contact ACE to setup bridge; we will not supply Datagrabber for ACE users. ACE has SDK integration with Easydent4 and can make it work with EZDent-i though there is a charge from their support.  NOTE: Data grabber can be supplied to older ACE users -only using the MDB type not the updated SQL based* Full Integration Bridge Bridge    
Alpha Dent   DIA-XV        
Alta Point   S        
Autopia   DIA-XV        
AVI Mark   S        
Axium   (by Henry Schein One)  Must have Version 7.11 or higher, must have or purchase Linked Apps from Axium - ‘VATECH Linked Apps Integration’ Bridge   Bridge    
Bridge IT   Full Integration        
Cadi (Synca)   Bridge Bridge Bridge Bridge/Twain AutoAdvance
Camsight CDM   DD        
CareStream "CS" software Carestreamconfirmed bug on the 7.0.1 version it will not take twain.
Please advise office to downgrade to an earlier build when you see this until update is availilbe.
      Twain* Twain*
CareStack Pano images - use
"Documents" tab
I/O for Sensors
    Bridge Twain AutoAdvance
CDR Dicom         Twain Twain
Centricity   DD        
CIEOS Bridge available for older versions* Bridge Bridge   Twain Twain
CleoSoft Need to confirm*          
Computer Age Dentist   Full Integration        
ClearDent     Bridge      
Cloud 9  Setup by Cloud 9 Bridge/Twain       Twain Twain
Cornerstone   Full Integration        
Curve Dental Direct Integration for Sensors availible* and twain for P2 units       Twain Twain
Curve (Hero) For twain they must purchase imaging contract       AutoAdvance AutoAdvance
Data Team   S        
Dental Mate   S        
Dental Works   S        
Dental.com   S        
Denticon       Bridge Bridge & Twain
DentalVision Henry Schein | Easydent4 only. S Bridge      
Dentech by Softech   DIA-XV        
Denti Max *Latest version requires special setup by Dentixmax; requiring the following folder and file to be inplace on all workstations (C:\VCapturesw\exe\NCSW_2012.exe) only the one .exe is required no other files* can simply copy and paste and call to dentimax for the integration to be setup. Also; for updated VCaptureSW.exe versions dentimax will need to update their link.  Full Integration, DIA-XV   Bridge Twain Twain
Denti Soft   Full Integration        
Dentrix Enterprise & IMAGING DataGrabber only* Full Integration   Bridge Twain Twain
Dentrix G5/G6         Twain Twain
Dentrix G7 & Higher Direct SDK Bridge for EzDenti- Must update to G7 and Smart Imaging Link Full Integration   Bridge AutoAdvance AutoAdvance
Dentrix Ascend (Cloud based) Skip function not supported* NS     Twain AutoAdvance
Dexis AutoAdvance in Dexis 10 or higher only.  NS     Twain Twain /AutoAdvance
Dexis imaging (Cloud based) (basically is Dentrix Ascend) Line 36         Twain AutoAdvance
Diamond Dental Software (DDS)*   DD, DIA-XV        
Discus   S        
DOC-AIDE   Full Integration        
Domtrak   S        
Dolphin (CLoud) A few sites have inidcated it does not always work stream lined after each scan they have to close Doulphin cloud after maybe 1 or 2 scans.  NS     Twain  
Dolphin  See legacy SDK chart. NS     Twain Twain
DSN/Perio-Exec Bridge avialilbe for Easydent4, *****EzDent-i bridge is Beta for version 16 and higher only.   Bridge Bridge    
DVMax   S        
E.Z.   Full Integration        
Eaglesoft *   Full Integration     Twain AutoAdvance
Easy Dental   Full Integration   Bridge    
eClinical     Bridge Bridge    
EMAGO          Twain Twain
EasyDent aka EzDent  *   Full Integration        
Evidentiae Twain has been verified       Twain Twain
Exan     Bridge      
Exact Dental   Full Integration        
Excel Dent     Bridge      
First Pacific Corporation (Aspire) Aspire is the PMS name Full Integration, DIA-XV        
Genesis   DIA-XV        
SOFTWARE NAME   I – Z Special Nots: Apteryx/DG Bridge EasyDent EzDent I NCSW HD Sensor
ICE Classic (Web based IE IMS) .JPG or .PNG Save format* NS     Twain Twain
iDent Cloud based - *They must change wait image to false* and flip the image default 'vertifcal       Twain* Twain
ImageXL (by PEB Software)  Requires Special setup* by PEB, does not pass gender   Bridge Bridge Bridge/Twain SDK/Twain
Innova   S        
Intellident   Full Integration        
IntraVet   S        
Julie   Full Integration        
Logic Tech Paradigm   DIA-XV        
MacPractice  (running windows Parallels) DIA-XV        
Maxident   DIA-XV        
Mediadent   S        
Medims Last known version in 2009*   Bridge      
meerMANAGER   S        
Maxim     Bridge      
MiPacs (Hospital Grade Server set) also GEPACS* Bridge: AnyGateway
Twain: Using Dental Enterprise Viewer*
Sensor: Autoadvance
DIA-XV     Bridge/Twain Bridge/Twain AutoAdvance
MOGO Has direct bridge available for EzDent-i VTEzBridge32.exe (Older versions) VTEzBridge.exe (newer versions).

Must set path for it to work by checking "Vatech" box then click cmd to set path
Full Integration        
NextGen   S        
Oasys - Crossfire *Need confirmation       Twain Twain
OMS Vision/DentalVision  Old OMS/DentVision Versions only* DIA-XV Bridge      
Oryx         Twain Twain
OMSVision* New Versions* S        
OpenDental * Has free bridge under "preference"
*Must have latest version
Full Integration Bridge Bridge Twain* Twain*
OpenDental/PracticeWeb   DIA-XV   Bridge    
Oral Exe/Dental Exec/Perio Exec   DIA-XV        
Oral Surgery Exec  Oral Exec-Dental Exec-Perio Exec S        
Ortho2 Ortho II is known to not work well with twain; and does not auto import; it will work but with special user sequence to manually import the image post-capture.  TNS*     Twain Twain
OrthoTrack  End User Must have SQL login for connection. Full Integration     Twain Twain
OrthoWare   Full Integration        
Patient Base   Full Integration        
PBS Endo PBS Endo has their own bridge to XV.  DIA-XV        
Perfect Byte ( PByte )   Full Integration        
PerioVision/EndoVision   DD        
Planet DDS Including Denticon Web based DIA-XV   DIA-XV Twain Twain
Practice Web  Resold version of OpenDental Full Integration Bridge Bridge    
Practice Works * If XV is used we can bridge from XV (With EU updating any missing demographics manually in XV First) - other wise no support*
 for Easydent4*
" - EzDent-i uses only sniffer to pass but must be updated version of EzDent-i. 
S, DIA-XV        
PrimaDent   DD        
QSI Denetal   DIA-XV        
Radiology Lab Management Systems (RLMS)   DD        
ScanDent   S        
ScanX       Twain    
SOTA         Twain Not Tested
SiDexis Twain does not properly function in SiDexis - Manual import only       Not Supported Not Supported
Softdent   Full Integration        
SoPro         Twain Twain
Suzy Dental4 SDK* patient data into Easydent4*   Bridge      
Tab32         Twain Bridge/Twain
TDOCS   S        
The Digital Office (TDO)   DD     Twain Twain
TIger View  *Most capture programs should twain* - Tiger View Classic is no longer supported; TigerView will charge $2K for support.        Twain Twain - Single capture only. 
Tiger View Pro *Auto Advance is supported per TigerView support       Twain Twain*
Time   DD        
Tops Ortho (All versions)  Tops is a MAC based system and is not able to integrate to windows platforms, the only option we have is to export the image to a file directory on the network somewhere that Tops is also able to see and manually import the file* - NO twain support NS     NS NS
Tracker Bridge availilbe and setup/supported by Tracker directly*       Bridge/Twain Bridge/Twain
VersaSuite   S        
Visiodent   S        
VixWin (all versions)  *Must use the older twain DS type to work, does not support newer twain version       Twain Twain Single capture only. 
Visix (Air Techniques)  Visix, which is a rebranded version of Tigerview.        Twain Twain Single capture only. 
VistaDent         Twain  
Walrus   S        
Windent Direct integration does not apply to KDI versions S        
WinOMS Cloud (Citrix) Special Setup required S     Twain Twain
WinOMS  Easydetn4- No support: Same as Practice works "If XV is used we can bridge from XV (With EU updating any missing demographics manually in XV First) - other wise no support for Easydent4*
 - EzDent-i : uses only sniffer to pass but must be updated version of EzDent-i. ; Patient will pass data but will not pass Gender but will add the patient , the end user will have to input /modify the chart to add this missing information before scanning patient else an error will occur. .
S     Twain Twain
XDR (IMS)          Twain Twain
XRay Vision (Apteryx) Full Integration / SDK & Twain (XrayVision, OneView; Prof Suni, ImageXL) - For XVCloud - See XVCloud. Full Integration Bridge   Twain Twain
XNAV (GUIDE Software) Uses login TSDF to access data*   Bridge      
XVCloud 2D Only, Does not accept updated 3D Images with higher resolution.   Bridge   Twain Twain

Key Guide:

To use the Integration Chart, first locate the Software in the Software Name Column. 1, Next you will have any special notes such as limited functionality or anything that has been recorded which is important to note. Each column after this represents the corresponding key below and their meaning.

1. Apteryx/DG Bridge: This section indicates what functionality Datagrabber or Apteryx Program such as XrayVision is capable of obtaining from the corresponding program to it self. Typically if using Datagrabber to passing information to Vatech programs all modes in this section with the exception of limited Sniffer will work and bridge patient information in some manner to Vatech Software. Vatech Software is fully compatible with Apteryx program, the limitation is what Apteryx is able to obtain and pass alone.

Bridge= Built in Bridge or Button from Calling Application to Apteryx/XVvision or other rebranded version IMS (No Datagrabber Support).

Full Integration= Full bridge functionality support via Datagrabber (To 3rd party such as Vatech Software) or SDK (To XrayVision/Rebranded)

Datagrabber= DataDrill functionality only to 3rd party software via Datagrabber. This indicates all required fields are obtainable via Datagrabber to pass to Vatech Software.

Sniffer= Sniffer only - indicates limited ability to pull data, typically does not pull all required data, manual imput of missing data required once charting is passed.

Note: Only EzDent-i supports the use of sniffer, Easydent4 does NOT support the use of Sniffer. It can only be used once the chart is manually entered to pull up the chart afterwards.

NS=  No support

 

2. Easydent4/EzDent-i - This column represents the ability for the calling appication to bridge directly passing patient information to add or open charting in Vatech Software.

B= Built in Bridge or Button from Calling Application directly into Easydent4 or EzDent-i.

NS=  No support

 

3. NCSW (SDK) Capture Program / HD Sensor - This column represents the ability of the calling application listed to directly call to the capture program either by SDK - passing patient information and saving directly or using Twain.

Note: Not all programs capable of twaining are listed, those listed are simply one's that have been confirmed to work. Most twain compliant programs  will support twain*.

T= Twain 2D images directly into the calling application. No patient information is shared.

B= Bridge directly from calling application, or SDK to Capture Software. .

NS= No support

Note: Please contact those software's that are not listed to confirm they support twain.

 

Support Contacts

 

All listed are subject to change with out notice, Vatech America does not have any control over the functionality of any linking software SDK or Datagrabber useage. Please review the following information for proper support channels.

  • Datagrabber - All requests or service should be directed at Apteryx Support.
  • SDK - All requests or service should be directed at the respected manufacture of said 3rd party software. This includes linking from IMS to Ez3D Plus/Ez3D-i
  • Twain - Typically most twain equipped software will function with out issue, there might be unknown variables or limitations when working with Twain* subject to respected manufacture support. All testing should be done first via 3rd party test tool to confirm Vatech Twain functionality beforehand.
  • Vatech Twain is typically installed during installations. Please also see: Installing Twain Topics for any installation assistance or Vatech Support.

Related Tags

Counts indicate more articles with the same tags

Related Products

Counts indicate more articles with the same products