Please use the following search box to quickly locate valuable FAQ support guide.
You can use key words or full statement to search by. Alternatively you can simply browse by Category belowWhen trying to run the migration tool, you only see the report after the previous instanceThere is a way to reset the program. You just need to enable it. Go to the settings in the VTMigrator and open up MGConfig.ini. As seen below. There you will find ShowResetButton. Type True after the equal sign You will now have a reset butto...
CONTINUE READINGHow to change Port number in Service based version 3.xx EzServer 'EzWebService'. This guide should only be used by Certified IT consultants or manufacture trained technicians when the default port is blocked. Open the windows key to bring up the search menu Type “server” in search. Open the Server control pannel as shown b...
CONTINUE READINGThe file path should DSN point to EzDenti for direct bridge is C:\Program Files (x86)\Vatech\EzDent-i\Bin\VTEzBridge32.exe
CONTINUE READINGIn some cases, when bridging 3rd party PMS software via - DataGrabber to EzDent-i - the CT button does not open capture software.When pressing the CT or Pano buttons it does not properly run even if running EzDent-i as Admin. To solve this issue all software must be ran as admin, PMS software --> DataGrabber (Located on server typical) --&g...
CONTINUE READINGHow to recover Postgresql Patient DB using VTDB Back up.exePlease note that this should not be relied on as the primary way to of backing up the Ezdent-I/EzServer Database.
CONTINUE READINGFirst access the EzDent-i menu by Clicking the EzDenti logo in the upper left hand corner, and click on Settings from the drop down menu Click on the Linkage/Email tab For Primary Viewer Option: To Use Ez3D Plus as primary viewer, click the 3D Viewer drop down menu and select Ez3D Plus From the 3D Viewer Path click the ... but...
CONTINUE READINGIt is highly recommended that this guide be used only by qualified IT Consultants to move or merge EZDent-i database in accordance with HIPAA. All proper backups must be made in advance of conversion process. Vatech America holds no liabilty in the event of failure to follow recomendations or proper adhearence to conversion process steps. WAR...
CONTINUE READINGHow to convert Easydent4 to EzDent-i Conversion guide for IT consultant. Before proceeding, please verify that you have a proper, working backup. If not please follow these guides on DB Back Up for your Software System:Easydent 4: https://vatechamerica.com/faq/easydent4/how-to-move-or-backup-easydent4-databaseEzdent-i: https://vatechamerica.co...
CONTINUE READINGActivation Process: 1. Before you begin you should have received a key list, typically this is located on the installation USB drive or Provided to you through order request, email and so on.Example Key List: Note: for 3D Users you will also have keys for Ez3D-i typically found in the same file. 2. Open the software that you are needing to update e...
CONTINUE READINGBefore linking Mesh Mixer software in EzDent-i your IT or support of Mesh Mixer should install the program first before proceeding and confirm the software works normally. First access the EzDent-i menu by Clicking the EzDenti logo in the upper left hand corner, and click on Settings from the drop down menuClick on the Linkage/Email tab U...